Steam Boiler:
Kind:
Tube:
Dimensions:
Length:
Diameter:
Tube desc:
Steam tube diameter:
Steam Furnace Kind:
Furnace length:
Furnace width:
Furnace height:
Steam heat surface:
Steam grate surface:
Number of grate bars:
Kind of grate bars:
Steam fuel:
Steam safety valve:
Steam max pressure:
Steam working pressure:
Steam diam of smokestack:
Smokestack height:
Drum dimension:
Steam Drum diameter:
Steam covering:
Steam boiler condition:
Steam boiler built:
Where built:
Manufacturer:
Steam heater:
Kind:
Size:
Heater time affect:
Steam Engine kind:
Steam Engine revolution:
Steam Engine cyl diameter:
Steam Engine piston stroke:
Steam Engine pipe size:
Steam Engine when built:
Steam Engine where built:
Manufacturer:
Outer & inner steel shells, semi-circular head
Steam, marine
Flue tube
height 7' 5"
6' 6"
width 4' 9"
102 tubes, 58" long
2.5"
Part of boiler, elliptical head
5'
4' 3"
1' 6" avg.
393.95 sq. ft.
21.25 sq. ft.
17 double & 1 single
Double bar, spade end.
Bituminous coal
Lavinges safety valve.
127#
85#
2' 2"
37'
5'
30"
none
fair
1899
York, PA
Geo. F. Motter & Sons
Upright
5"
9"
3 1/4"
1899
Baltimore, MD
Ellicott Mach. Co.
Steam Signal
Whistle diameter:
Whistle height:
Whistle orifice:
Whistle tone:
Whistle chime:
10"
2 3/4"
single
Whistle Signal
Home | About Us | Magazine | Membership | Lighthouse Passports | Tours | Lightship | Resources | Store | Contact Us | Site Map