Lantern:
Illuminating Apparatus:
Service Lamp:
Oil:
Service Lamp Burner:
Service Lamp Burner Level:
Plate Glass:
Lens Cover:
Lantern Curtains:
Carillon or Alarm Bell:
Rod Lamp:
Dwelling:
Stairway and Landing:
Inside of tower:
Glazing of Dwelling:
Improvements Needed:
Outhouses:
Boathouse:
Grounds:
Lighthouse Inspection Reports Database
Lazaretto Point Light Station - 1870
Inspection Reports Page 1 of 2
In good condition.
Lens in good condition & clean in every part.
In good condition & very clean.
Oil was found to be free from all dust, dirt or motes & had not been filtered.
In very good condition with no gummy or burnt oil attached to it. Wicks are well trimmed.
It is level.
Quite clean & free from scratches stains or dirt.
It is on, clean & made of linen ticking hung up in the Lantern room when not in use.
2 sets containing 16 pieces, in good condition, put up & taken down at the proper time.
There are none required.
Rod lamp in good condition.
Dwelling is in good condition. The roof requires repair.
Clean & painted.
In good condition, whitewashed.
In good condition
1 of the outhouses requires repairs.
Fair condition
In very neat condition. They appear very clean & neat.
Report Sections:
Premises | Lantern and Fixtures | Ventilators and Watchroom | Illuminating Apparatus | Closets and Storerooms
Fog Signal General | Fog Signal Equipment | Dwelling | Asst. Keepers Dwellings | Water | Healthfulness
Lighthouse Access | Station Boat Info | Tools and Accessories | Light Vessel Specific | Inspection Reports
Supplemental Reports
Condition of:
Home | About Us | Magazine | Membership | Lighthouse Passports | Tours | Lightship | Resources | Store | Contact Us | Site Map
© 2006 United States Lighthouse Society · 244 Kearny Street 5th Floor, San Francisco CA 94108 · ph. 415.362.7255
Lens:
Lantern and Trap Doors:
Watch or Trimming Room:
Lucernes or Matches:
Heater:
Ventilation:
Dome:
Lens is never touched improperly.
They fit properly.
There are none of these to be seen at the time of Inspection.
There were none of these articles found about the rooms.
The keeper understands the use of the heater.
Keeper understands the use of the ventilators, & how to air the bldg.
Painted according to Instruction. Lightning Conductor was in good condition & let into the ground
Equipment Care
Does Keeper Understand the Use and Care of:
Oil Room:
Oil Carriers:
Clean & seemed to have had attention paid to ventilation.
In good condition & well arranged.
Oil Room
Condition of:
Number of:
100 gallon oil:
50 gallon oil:
Small butts for Waste Oil:
Dripping Buckets:
Oil Tanks:
3
3
3 holding 150 gallons.
Oil butts made according to regulation:
Oil butt covers:
Drip Bucket Placement:
Oil Butt Platform:
Empty Oil Butts:
They are so made.
Gutters were filled with refuse oil & covers on. Keeper understands the use of the covers & air cocks.
There was one so hung.
They are placed upon a raised platform of plank.
There was 1 empty oil butt, clean & ready for use.
General Information: