Lantern:

 

Illuminating Apparatus:

 

Service Lamp:

 

Oil:

 

Service Lamp Burner:

 

Service Lamp Burner Level:

 

Plate Glass:

 

Lens Cover:
 

 

Lantern Curtains:

 

Carillon or Alarm Bell:

 

Rod Lamp:

 

Dwelling:

 

Stairway and Landing:

 

Inside of tower:

 

Glazing of Dwelling:

 

Improvements Needed:

 

Outhouses:

 

Boathouse:

 

Grounds:

Lighthouse Inspection Reports Database

Pooles Island Light Station - 1867

Inspection Reports Page 1 of 2

In good condition

 

Lens was in good condition & perfectly clean in all its parts.

 

In good condition in all respects.

 

Specimen examined & found to be clear & clean - it had been filtered,

 

In good condition & free from gummy or burnt oil.

 

Burner was found to be level.

 

Very clean, free from scratches, stains & dirt.

 

It was on; not very clean - was made of cotton ticking, and kept in the lantern room when not
in use.

 

none

 

none

 

none

 

Dwelling is now under repair & will soon be in good condition.

 

Clean & whitewashed.

 

Whitewashed throughout.

 

In good condition

 

Do not know of required.

 

2 of the outhouses are falling to pieces. They are not considered worth repairing.

 

There are none

 

In good condition. Grounds appear to be well cared for.

Report Sections:

Premises | Lantern and Fixtures | Ventilators and Watchroom | Illuminating Apparatus | Closets and Storerooms

 

Fog Signal General | Fog Signal Equipment | Dwelling | Asst. Keepers Dwellings | Water | Healthfulness

 

Lighthouse Access | Station Boat Info | Tools and Accessories | Light Vessel Specific | Inspection Reports

 

Supplemental Reports

Condition of:

Home | About Us | Magazine | Membership | Lighthouse Passports  | Tours | Lightship | Resources | Store | Contact Us | Site Map

© 2006 United States Lighthouse Society · 244 Kearny Street 5th Floor, San Francisco CA 94108 · ph. 415.362.7255

Lens:

 

Lantern and Trap Doors:

 

Watch or Trimming Room:

 

Lucernes or Matches:

 

Heater:

 

Ventilation:

 

Dome:

It is not allowed to touch the lens improperly.

 

They fit tightly.

 

no

 

no

 

no heater

 

Keeper understands use of ventilators & how to air the bldg.

 

They were so painted. Conductor was in good condition & led into the ground.

Equipment Care

Does Keeper Understand the Use and Care of:

Oil Room:

 

Oil Carriers:

In bad condition - there was a waste of oil on the floor.

 

Only tolerable.

Oil Room

Condition of:

Number of:

100 gallon oil:

 

50 gallon oil:

 

Small butts for Waste Oil:

 

Dripping Buckets:

 

Oil Tanks:

 

 

2

 

 

 

3

 

2 holding 100 gallons

Oil butts made according to regulation:

 

Oil butt covers:

 

Drip Bucket Placement:

 

Oil Butt Platform:

 

Empty Oil Butts:

 

 

Gutters were not filled. Keeper was instructed in regard to them & to the air cocks.

 

No; Keeper's attention called.

 

On plank raised from floor.

 

There were no empty oil butts.

General Information: